9 Pin UHV Female PEEK connector to round cable assembly.
9-Pin UHV Subminiature-C Female PEEK connector to Kapton® insulated Round/Circular cable, leads in 19" or 39" lengths.
9-Pin UHV Subminiature-C Female PEEK connector to Kapton® insulated Round/Circular cable, leads in 19" or 39" lengths.
9-Pin UHV Subminiature-C male PEEK connector to Kapton® insulated Round/Circular cable, leads in 19" or 39" lengths.
2x 9-Pin Subminiature-C female connectors / Kapton insulated cable leads 19" length.
9x Female socket contacts / Kapton insulated cable leads in 19" or 39" lengths.
9 Way Circular Kapton Cable with Pins (Male) on one end, 19" or 39" lengths.
AGP vacuum compatible connector-to-cable assemblies are fitted with PEEK Subminiature-C female or male connectors on one end, and nine non-terminated color-coded leads at opposite end. Female cable connectors mate directly to the vacuum side of all Subminiature-C UHV and HV feedthroughs, and/or with other PEEK male connector fitted extension cables. The cable’s outer jacket is a woven PEEK monofilament braid producing a nominal outer cable diameter of 0.14 inches. These cable assemblies are fitted with nine, Kapton® insulated 28 AWG leads, each of which is composed of seven 0.005 diameter twisted strands of silver-plated copper wire.
AGP also offers connector-to-connector, female/female UHV rated extension cable assemblies that are 19-inches in length, fitted with PEEK Subminiature-C female connectors at both ends.
Contact-to-cable UHV cable assemblies are an economical in-vacuum connectivity solution, wherein contacts are individually pushed-on to their corresponding feedthrough pins. They are ideally suited for applications requiring single and/or infrequent connection cycles. These UHV cable assemblies are fitted with crimped male or female contacts on one end, and with non-terminated, Kapton insulated, leads at the other.
Caution: Please note that contact-to-cable assemblies are an economical connectivity solution, as such these cables do not include PEEK connectors, nor will they allow PEEK connector installation at a future date. Crimped contacts are too large for insertion through the PEEK connector’s back-piece. Generally, cable wires must be threaded through the connector’s back-piece before contacts are crimped to their respective wires.
Electrical 1, 2 | |
Voltage | 500VDC |
Current | 5A |
Material | |
Connector 3 | PEEK |
Braiding, Monofilament | PEEK |
Insulation, Wire | Kapton |
Wire, 7x.005 Stranded | Ag-Plated Cu |
Vacuum Range 4 | |
UHV, Ultrahigh Vacuum | 1x10-10 Torr |
Temperature Range 4 | |
Connector / Wire | -75 to 250°C |
Notes |